Saputra, Rezeki Indra (2022) ANALISIS PENGARUH INJEKTOR TERHADAP KINERJA POMPA SENTRIFUGAL SUSUNAN PARALEL. Sarjana (S1) thesis, Universitas Islam "45" Bekasi.
Text
PENDAHULUAN.pdf Download (1MB) |
|
Text
BAB 1 PENDAHULUAN.pdf Download (149kB) |
|
Text
BAB II LANDASAN TEORI.pdf Restricted to Repository staff only Download (1MB) | Request a copy |
|
Text
BAB III METODOLOGI PENELITIAN.pdf Restricted to Repository staff only Download (215kB) | Request a copy |
|
Text
BAB IV PEMBAHASAN.pdf Restricted to Repository staff only Download (450kB) | Request a copy |
|
Text
BAB V PENUTUP.pdf Download (285kB) |
|
Text
DAFTAR PUSTAKA.pdf Download (373kB) |
Abstract
Research related to the analysis of the effect of installing an injector on a parallel arrangement centrifugal pump whose testing process was carried out using two JETS60 type centrifugal pumps with the type of working fluid being water at a temperature of ±30⁰C. The research was carried out by taking pump data in a circuit without an injector and with a pump circuit adding an injector to 3 valve opening variables, namely 3/4, 1/2, and 1/4. And from the results of research and processing of tool test data, obtained analysis data for calculating the total pump head, where the total pump head value without the installation of the 3/4 valve opening injector is 5.18 m with a flow rate of 0.00128 m3⁄s, valve opening 1/2 the total head value is 3 m with a flowrate of 0.000746 m3⁄s and the valve opening is 1/4 the total head value is 2.59 m with a flowrate of 0.000426 m3⁄s. While for pumps with additional injector installation, the total head value of 3/4 valve opening is 2.9 m with a flow rate of 0.000853 m3⁄s, valve opening 1/2 total head value is 2.4 m with a flowrate of 0.00064 m3 s and valve opening 1/4 the total head value is 1.27 m with a discharge of 0.0002 m3⁄s. From the overall data, it was found that there was an increase in the total head value for variations in valve opening settings, where the highest total head value was obtained at 3/4 valve openings in the pump circuit without injector installation. From the two types of circuits, it can be seen that there is a decrease in the total head value along with the decrease in the value of the discharge / capacity at the pump. So the relationship between the total head and the discharge is directly proportional. Keywords : Centrifugal Pump, Injector, Parallel Circuit, Pump Head, Discharge
Item Type: | Thesis (TA, Skripsi, Tesis, Disertasi) (Sarjana (S1)) | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Contributors/Dosen Pembimbing,NIDN Dosen bisa diakses di LINK https://bit.ly/NIDNdosenunismabekasi: |
|
|||||||||
Keywords / Kata Kunci: | Centrifugal Pump, Injector, Parallel Circuit, Pump Head, Discharge | |||||||||
Subjects: | Konversi Energi | |||||||||
Faculty: | Fakultas Teknik > Teknik Mesin S1 | |||||||||
Depositing User: | Users 223 not found. | |||||||||
Date Deposited: | 19 Aug 2022 09:21 | |||||||||
Last Modified: | 19 Aug 2022 09:21 | |||||||||
URI: | http://repository.unismabekasi.ac.id/id/eprint/690 |
Actions (login required)
View Item |